Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W
Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W

Wall Split Air Conditioning Mitsubishi Heavy Industries SRK25ZSX-WT/B + SRC25ZSX-W

1,995.29 €

Taxes included

Price without taxes: 1.649,00 €

Calculate Delivery Cost

Check your shipping costs when processing the order

Quantity

Buy now, with the convenience of being able to pay in monthly instalments!

Only available for citizens and residents in Spain

Wall Split AC brand Mitsubishi Heavy Industries.
Cooling Capacity: 2.150 Kcal/h (2.50 kW)
Heating Capacity: 2.752 Kcal/h (3.20 kW)
EU Ecolabel (Refrigeration): A+++
Gas: R-32

ClimaMarket, Entidad adherida a CONFIANZA ONLINE

Seal of Online Trust. Purchase and browse without worries through our web store.

Energy Saving.

Eco Operation

Automatic energy saving control is done by detecting human acitivity. Human activity is detected by motion sensor which is installed in the unit. Air conditioner adjust its cooling/heating capacity according to low/high demand. Economy Cooling operation,  Air conditioner controls its capacity lower and goes into energy saving control when low activity is detected. Economy Heating operation,  Air conditioner controls its capacity lower and goes into energy saving control when high activity is detected. When the sensor detects that no people are present in the room, the unit will automatically reduce the power used to a moderate level after approximately 15 minutes and return to normal operation once people return to the room.

Auto Off

Air conditioner stop operation and goes to “stand-by” mode after 1-hour absence. It turns ON again when human activity is detected within 12-hour,or turned OFF after 12-hour absence

Fuzzy Auto Mode.

The temperature and humidity sensors check room conditions. The unit automatically controls the operation mode and the setting temperature to operate efficiently. Operation mode and cooling/heating capacity is controlled automatically according to one setting tempertature. Fuzzy auto mode offers automatic comfort temperature control even if weather condition changes quickly.

AirFlow

Jet Air Technology Long Reach Air Flow

We used the same aerodynamic analysis technology as used in developing jet engines. Quiet Air Flow & Long Reach.

CFD (computational fluid dynamics), used in blade shape design of jet engines, has been applied to the design of air channels in air conditioners to develop the ideal air channel system (air circulation). The jet air stream generated by this air channel system can bring large volume air without consuming much power. While at the same time, it delivers a uniform gentle breeze to every corner of the room.

Long Reach Air Flow

Long reach air flow is realized by Jet technology. Good for large living rooms and shops, which increases comfort.

Double Flap  Large and Small.

Double flaps can control optimized air flow, horizontal and long reach air flow in cooling, strong and downward air flow in heating, which can produce comfort room temperature condition.

3D AUTO Multi motors make 3 independent controls

3D AUTO is one touch programmed and multi motors make three independent air flow controls. The uniform and quiet airflow can be delivered to every corner of the room, achieving economical operation and minimizing energy loss. 

Thanks to automatic control of air flow volume and air flow direction, comfortable air conditioning of the entire room can be done effectively. The cooled air flows directly to the ceiling in cooling operation mode, not directly at the occupants of the room. Comfort cooled air flow comes via the ceiling like a cool breeze. In the heating mode, warm air flow can be sent down to the floor directly. The warm air then spreads along the floor achieving optimum comfort.

Clean Air

Allergen Clear Operation

This can be activated by pressing the “allergen” button on the remote control and lasts 90 minutes before stopping automatically. It neutralizes all the bacteria collected on the surface of the anti-allergenic filter thanks to its sophisticated interaction between temperature and humidity controls.

Self Clean Operation

Self clean operation is operated for 2 hours after the unit has stopped its normal operation. The indoor unit is dried up and the growth of mold is restrained. Users can select whether this mode is utilized or not.

Structure of Preventing Dirt

The fan has undergone anti-microbial treatment to resist mold and germs, making the system clean and safe. Foul odours and molds, etc. which can occur when an air conditioning system is not in operation are prevented.

Allergen Clear Filter

The allergen clear filter breaks down the pollen*1, lice*1, and allergens that live on cat skins, etc. and deactivates them. The secret of deactivation is the Enzyme-urea compound. It deactivates not only allergens but also all kinds of bacteria*2, molds and viruses*3. Even if allergens and bacteria, etc. fly of the filter, they are deactivated, so the air in your room is kept fresh

Photocatalytic Washable Deodorizing Filter

It will keep the air fresh by deodorizing the molecules causing odour. Its deodorizing power can be restored by washing with water and drying under the sun, as such it is a Recycling deodorizing filter capable of repeat use.

Comfort

High Power Operation

In a cooling operation

This operation mode delivers powerful cool air to cool the room quickly. It blows powerful cool air when you want to be cooled down after bathing or returning home on a hot summer day so that you can enjoy a cool sensation immediately. The air conditioner automatically returns to the previous operation mode in 15 minutes to prevent the room from being cooled excessively.

In a heating operation

This operation mode warms the whole room from the vicinity of the air conditioner to your feet. It warms up the room promptly when you want to be warmed such as getting out of bed or returning home during the winter seasons. The air conditioner automatically returns to the previous operation mode in 15 minutes to prevent the room from being warmed excessively

Silent Operation

When Silent operation is set, the maximum pressure level of the outdoor unit will be 3dB(A) lower than standard nominal level (45dB(A) or less). The compressor speed is set at a lower range than that of nominal operation, operating at 60% of nominal capacity. Maximum fan speed of outdoor unit is set lower than nominal operation.

Night Setback

During cold seasons, room temperatures can be maintained at a comfortable level even while the room is unattended. The air conditioner keeps the temperature at 10°C.

Timer / Convenience

Weekly Timer Up to 4 programs with timer operation (ON-TIMER / OFF-TIMER)  are available for each day of the week. Maximum 28 programs per week can be set. Once set, the timer operation will repeat the same  program every week unless otherwise canceled.

Sleep Timer Too much cooling/heating is not necessary when people go to sleep. This function achieves moderate cooling/heating by adjusting its capacity and more energy saving as well. 

Comfort start-up Air conditioner controls room temperature to achieve confort at the “set time” by 60-minutes pre-operation. This is convenient when you wake up and return home at a predetermined time. In ON-TIMER operation, the unit starts the operation a little earlier, so that the room can approach optimum temperature at ON time.

Preset Operation The Preset Operation features allows customised temperature and airflow settings, which will deliver ultimate comfort with one simple touch of the button. (Applied for ZSX & ZS series)

LED Brightness Adjustment Brightness of the LED display can be adjusted to suit. (Applied for ZSX & ZS series)

Easy to remote control The wall mounted unit comes with a wireless infra-red remote controller which is used to control the unit’s settings such as temperature, fan speed, heating or cooling mode. The controller has a user-friendly design with large buttons. There are many key benefits such as eco-mode settings, which allow energy to be saved. There is also a weekly timer which can be set to your own parameters and when required for your convenience. There is also a silent mode option, which can be selected when going to sleep so there are minimal noise levels.

Wide Range of Operation 

Our new advanced technology has expanded the heating and cooling operation range. This permits installation of the units considering a heating and cooling operation under a low temperature condition down to –20°C. (ZSX series) 

Long Piping Length ZSX series supports a piping length of up to 30m to give design flexibility.

YOUR AIR CONDITIONER ALWAYS WITH YOU

Control the Air Conditioning units through airconwithme® App in a very intuitive way. The App allows an easy and intuitive WiFi AC Control from anywhere via your smartphone or tablet.


SRK25ZSX-WT/B+SRC25ZSX-W

Data sheet

Indoor unit
SRK25ZSX-WT/B
Remote control
Yes
Outdoor unit
SRC25ZSX-W
Cooling Capacity
2.150 Kcal/h (2.50 kW)
Heating Capacity
2.752 Kcal/h (3.20 kW)
Gas
R-32
Heat Pump
Yes
Nominal consumption cold/heat
0.44 kW / 0.59 kW
Minimum sound pressure level (indoor unit)
19 dBA
EU Ecolabel (Refrigeration)
A+++
EU Ecolabel (Heating)
A+++
SEER / SCOP
10.3 / 6.6
Color indoor unit
Color
Wifi
Optional
Dimensions Indoor Unit (mm - H x W x D)
920 x 305 x 220
Dimensions Outdoor Unit (mm - H x W x D)
800 x 640 x 290
Total packages
2
Liquid pipe diameter
1/4
Gas pipe diameter
3/8